IMPORTANT: READ FIRST
SAVI LED UNDERWATER LIGHTS ARE LOW VOLTAGE FIXTURES. IMPROPER
WIRE GAUGE AND WIRE LENGTH CAN AFFECT THE PERFOMANCE OF THESE
PRODUCTS. FOLLOW THE GUIDES BELOW TO DETERMINE THE PROPER
OPERATION AND OPTIMUM PERFORMANCE OF SAVI LIGHTS.
!
WIRE GAUGE & WIRE LENGTH GUIDE
JUNCTION BOX
Black Hot Line
Crim
p Style Connectors
Recommended
Crimp Style Connectors
Recommended
BLK BLK
WHT
WHT
White Neutral
Green Ground
LOW VOLTAGE (12VAC) TRANSFORMER
PX100 or PX300
NOTE: This Diagram is to be used as a guide line only for a typical System Installation and should only be used
as such. It is the Installers sole responsibility to verify and assure that proper gauging of secondary wiring
from the Transformer to the J-Box are in compliance with your local, State and National Electrical Codes.
JBT
JUNCTION BOX
BUS BAR
PX100 / PX300 MAX WATTAGE
0-50ft 100ft cord
168W
12GA
12V
SAVI Pool and Spa | 9400 Southridge Park Court Suite 200 | Orlando | Florida | 32819 | USA | T. 407.855.5630 nextstepproduct.com
JBT
100ft 50ft cord
126W
10GA
12V
JBT
130ft 20ft cord
98W
8GA
12V
JBT
JUNCTION BOX
BUS BAR
PX100 / PX300
0 - 50ft 100ft cord
210W
12GA
13V
JBT
51 - 100ft 50ft cord
168W
10GA
13V
JBT
101 - 125ft 10ft cord
154W
8GA
13V
JBT
JUNCTION BOX
BUS BAR
PX300 ONLY
0-50ft 100ft cord
240W
12GA
14V
JBT
51 - 100ft 50ft cord
224W
10GA
14V
JBT
101 - 125ft 10ft cord
196W
8GA
14V
NOTE: The use of Solid Core over Stranded wire and terminating at Bus Bars is strongly recommended.
9400 SOUTHRIDGE PARK COURT SUITE 200 ORLANDO, FLORIDA 32819 USA
Tel: 407.855.5630 Fax: 407.210.8679 nextstepproduct.com
NOTE: Min. 12VAC: / Max 13VAC. The maximum run of service between transformer and lights should not
exceed 150ft in total length, inclusive of the use of J Box or not.
When J-Box used all voltage readings are to be taken at J-Box when all Lights are set on WHITE.
When Lights are connected directly to transformer, voltage readings are taken at transformer with Lights on WHITE.